155 E Broadway Rd.
Mesa, AZ 85210
480-832-9659

Local Reviews
for gold canyon, az

Rated 4.0 out of 5 stars based on 2 customer reviews

Okay Checkup

Disappointed in your service mans pricing for repair. I was able to purchase part for $40 and install in 5 minutes vs the $300 he wanted to charge. Would not use your services again due to this.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Chris was very courteous and professional. Great job

Chris was GREAT!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for gold canyon, az

Keith H.

Keith H. Job Checkin

PERFORM SRP INSPECTION. DIAGNOSIS: SYSTEM RUNNING NORMAL. STRAIGHT COOL WITH GAS HEAT. TESTED AMP DRAWS RUN CAPACITORS. FREON LEVELS. TIGHTEN ELECTRICAL CONNECTIONS. HOSED OFF THE OUTDOOR COIL AND FLUSHED THE CONDENSATE LINE. RECOMMEND REPLACING TWO CAPACITORS. 1- DUAL 45-5 FOR THE COMPRESSOR AND OUTDOOR FAN. 2 - 10MFD FOR INDOOR FAN. UNIT RUNNING FINE IN COOLING AT THIS TIME WITH A 20 DEG COOLING SPLIT.


Stuart M.

Stuart M. Job Checkin

PERFORMEDC PMP INSPECTION ON TWO PACKAGE CONVENTIONAL AC AND GAS FURNACE UNITS. CHECKED AMP DRAWS OF MOTORS TESTED RUN CAPACITORS FOR PERFORMANCE WITHIN MANUFACTURES RATING TIGHTENED ELECTRICAL CONNECTIONS VERIFIED TEMP SPLIT INSPECTED CONDITION OF UNITS WEST UNIT HAS OFM AT MAXIMUM AMP RATING (1.5) AND EAST UNIT HAS DUAL RUN CAPACITOR TESTING AT LIMIT OF MANUFACTURE RATING. BOTH ISSUES WILL BE TESTED AGAIN AT NEXT INSPECTION TO VERFY NO FURTHER LOSS OF PERFORMANCE. UNITS RUNNING IN COOLING AT TIME OF INSPECTION


Chris R.

Chris R. Job Checkin

PROBLEM FAN WON'T SHUT OFF CARRIER 48GX-036060301-- 2801G12198 DIAGNOSIS CYCLED THE UNIT SEVERAL TIME /CAN'T VERIFY ANY ISSUES AT N THIS TIME UNIT IS SHOWING VISIBLE WEAR RECOMMEND MAINTENANCE ON 2 UNITS


Chris R.

Chris R. Job Checkin

PROBLEM NO HEAT UNIT IS HEATING AT THIS TIME ISSUES COULD BE WEATHER RELATED


Keith H.

Keith H. Job Checkin

PERFORM INSPECTION ON TWO ROOFTOP PACKAGE HEAT PUMP SYSTEMS UNIT 1- GOODMAN 3.5 TON 1 YR OLD UNIT 2- TRANE 2.5 TON. 3 YRS OLD DIAGNOSIS: BOTH UNITS ARE HEATING JUST FINE. TESTED EQUIPMENT TO ENSURE PROPER OPERATION. AT THIS TIME BOTH UNITS ARE HEATING WITH A 30 DEG RISE. - TIGHTEN ELECTRICAL CONNECTIONS - TEST FREON LEVELS - INSPECT INDOOR AND OUTDOOR COILS, - INSPECT MOTOR AMP DRAWS - INSPECT CAPACITORS. - INSPECT ELECTRICAL CONNECTIONS AND WIRES. - TESTED DEFROST CONTROL BOTH UNITS ARE OPPERATING NORMAL AT THIS TIME. NO RECOMMENDED REPAIRS AT THIS TIME.


Chris R.

Chris R. Job Checkin

PROBLEM 37 PT INSPECTION @2 TRANE MASTER MFD-2/2013 4TWB4061E1000BB 1306412D2F DIAGNOSIS CONDENSER FAN MOTOR IS LEAKING OIL /THIS MAY CAUSE THE MOTOR TO FAIL IN THE SUMMER WHEN THE TEMPERATURES INCREASE CHECKED DEFROST CYCLE /NO ISSUES AT THIS TIME VERIFIED SEQUENCE OF OPERATION IN HEATING MODE AND THE UNIT HEATING WITH A 30 PLUS DEGREE TEMPERATURE SPLIT ACROSS THE EVAPORATOR COIL MOTOR AMPS AND RUN CAPACITOR ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME NO RECOMMENDED REPAIRS AT THIS TIME KITCHEN UNIT TRANE MFD-2/2013 4TWB4049E1000BB 130918W62F DIAGNOSIS 5MFD RUN CAPACITOR IS WEAK /RECOMMEND REPLACING /THIS WILL ALLOW INTERNAL DAMAGE TO THE MOTOR CHECKED DEFROST CYCLE /NO ISSUES AT THIS TIME VERIFIED SEQUENCE OF OPERATION IN THE HEATING MODE AND THE UNIT HEATING WITH A 30 PLUS DEGREE TEMPERATURE SPLIT ACROSS THE EVAPORATOR COIL NO OTHER RECOMMENDED REPAIRS AT THIS TIME TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COILS REPLACED 7.5MFD RUN CAPACITOR FOR